Mallory-ignition Mallory HYFIRE 7C CONTROL UNIT 676M Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Pour la voiture Mallory-ignition Mallory HYFIRE 7C CONTROL UNIT 676M. Mallory Ignition Mallory HYFIRE 7C CONTROL UNIT 676M User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 4
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
1
OPERATING INSTRUCTIONS
®
HYFIRE
®
7C CONTROL UNIT
PART NO. 676M
FORM 1554M (REV. A) 10/02
RPM Switch:
NOTE: This feature is not available on the HYFIRE
®
667S. The
built-in RPM switch can either turn an electrical load off or on
at a selected RPM. See below for more detail.
NC This is the RPM switch (mode 7) relay contact that is
normally closed. In other words, as long as you haven’t
reached the point where the RPM switch is active, this
contact remains connected to the “common” or “C” ter-
minal. You would use this connection if, for example,
you wanted to turn something OFF (such as a nitrous
system) when you reached the RPM switch point. See
Example 1.
C This is the common terminal for the RPM switch (mode
7) relay in the main unit. It is connected to the RPM
switch, where it will switch the accessory connected to
the “NC” terminal OFF, and the accessory connected
to the “NO” terminal ON when the RPM switch value is
reached. The “C” terminal can be used to switch either
to power or ground.
NO This is the RPM switch (mode 7) relay contact that is
normally open. In other words, as long as you haven’t
reached the point where the RPM switch is active, this
contact isn’t connected to the “C” contact. You would
use this contact to turn something ON (such as a shift
light or an air shifter) at a specific RPM. See Example 2
and Example 3.
RPM Limiters:
The HYFIRE
®
676M Control has three built-in RPM limiters. Each
one has a range of 1000 to 12,800 RPM in 50 RPM steps. On the
main display, there is a decimal point on the mode digit. When that
decimal point is lit up, the RPM limit is increased by 50 RPM.
RPM1 (Mode 1)This is the RPM limit that is always active if you
haven’t selected any other RPM limit.
RPM2 (Mode 2) This is an auxiliary RPM limiter that is acti-
vated when you apply 12 volts to the “RPM2” terminal on
the top-side connector. This could be a burnout limiter.
When selected, it overrides RPM 1 (the main engine
protection RPM limiter). See Example 4.
RPM3 (Mode 3) This is the other auxiliary RPM limiter. It also
is activated by 12 volts on the “RPM3” terminal on the
top-side connector, and overrides both RPM2 and
RPM1. Use this limit as a staging (starting line) RPM
limiter. See Example 5.
High Speed Timing Retards:
RET1, RET2, RET3 (Modes 4, 5, 6) These are all high-speed
timing retard functions that are activated by 12 volts on the appro-
priate top-side connector terminal. Each higher stage overrides
the lower stages, which means that you set each stage for exactly
the amount of retard you want, rather than adding up each stage to
get the actual retard. See Example 6.
NOTE: When you apply 12 volts to RPM2, RPM3, RET1, RET2,
or RET3 the display will switch to show that function. If you
have both an auxiliary RPM limit AND a retard selected, the
display will show the retard value.
See the accompanying illustrations for some examples of how to use
the RPM limiters, the RPM switch, and the timing retard functions.
Vue de la page 0
1 2 3 4

Résumé du contenu

Page 1 - 7C CONTROL UNIT

1OPERATING INSTRUCTIONS®HYFIRE® 7C CONTROL UNITPART NO. 676MFORM 1554M (REV. A) 10/02RPM Switch:NOTE: This feature is not available on the HYFIRE® 667

Page 2 - CONTROL CENTER

2R1 - RPML 12 - RPML 24 - RETARD 15 - RETARD 26 - RETARD 350 RPMSTEPS7 - RPM SWITCHP/N3 - RPML 3D - DEG / PSIE - MAP SELECT8 - HSA SLOPE9 - HSA CUT-IN

Page 3 - Example 4

3NCCNORPM2RPM3RET1RET2RET2COILTo +12 VoltsTo Nitrous SystemFrom Nitrous Activation SwitchCOILTo GroundCONTACTCONTACTRELAY—Use a relay if you are switc

Page 4 - Example 7

4MALLORY IS A DIVISION OF THE MR. GASKET PERFORMANCE GROUP550 MALLORY WAY, CARSON CITY, NEVADA 89701(775) 882-6600 FAX (775) 887-4326www.mrgasket.comF

Commentaires sur ces manuels